Congenital Cardiac Anesthesia Society
A Section of the Society for Pediatric Anesthesia.

Author: Anila B. Elliott, MD - C.S. Mott Children’s Hospital - University of Michigan

You are caring for a 5-day-old, 2.8kg term infant with tetralogy of Fallot and a confirmed left aortic arch with normal branching who was placed on VA ECMO via the right common carotid artery and right internal jugular vein following a cardiac arrest. They present for diagnostic cardiac catheterization to evaluate the etiology of their hemodynamic instability. While placing monitors you note that the pulse oximeter on the right upper extremity is 85% and on the left lower extremity is 100%. Pulse oximeter waveforms are reliable, and arterial blood gases in the extremities confirm the difference. Which of the following is the MOST LIKELY etiology?

Correct! Wrong!

EXPLANATION

Differential cyanosis is often defined as an inter-extremity difference in oxygen saturation of at least 5% or PaO2 of at least 20mmHg. 3 With classic right-to-left shunting across a patent ductus arteriosus (PDA), desaturated pulmonary arterial blood enters the descending aorta, producing a higher pre-ductal (right upper extremity) saturation compared to post-ductal oxygen saturation. A lower right upper extremity saturation represents “reverse differential cyanosis”. This can be found with specific anatomy, such as dextro-transposition of the great arteries (d-TGA) with a PDA and elevated pulmonary vascular resistance (PVR), d-TGA with a PDA and pre-ductal aortic interruption or coarctation, aberrant right subclavian connected to the right pulmonary artery by the PDA, and supracardiac total anomalous pulmonary venous return with PDA and patent foramen ovale (PFO).1-3

In rare instances on VA ECMO, reverse differential cyanosis can also result from cannula positioning and competing flow streams. If the arterial cannula directs well-oxygenated ECMO blood preferentially toward the distal aortic arch or descending aorta, while the native heart ejects poorly oxygenated blood into the ascending aorta, the coronary arteries and arch vessels (including the right subclavian artery) are perfused by desaturated native output and the lower body receives well-oxygenated ECMO flow. In tetralogy of Fallot, native output is desaturated not only from lung pathology or ventilator rest settings, but also from intracardiac right-to-left shunting across the ventricular septal defect and reduced pulmonary blood flow during VA ECMO. 1,3

This finding is clinically important because the heart and brain are the organs receiving desaturated blood, and monitoring lower extremity saturation alone can be falsely reassuring. In a reported infant case, withdrawing a carotid arterial cannula that had migrated too deep by approximately 1cm immediately reduced the saturation difference to less than 5%. 3 This physiology is related to differential hypoxemia, also known as Harlequin syndrome or North-South syndrome. This phenomenon is typically seen during peripheral femoral VA ECMO, when antegrade, poorly oxygenated native cardiac output flow competes with retrograde, well-oxygenated ECMO flow. 3,4

Initial evaluation should include the following:

1. Confirmation of reliable pulse oximetry and arterial blood gases from both extremities
2. Comparison of oxygen saturation in all 4 extremities
3. Imaging to assess return cannula position and jet direction
4. Assessment of native cardiac function/aortic valve opening
5. Evaluation of ventilator settings, pulmonary function, ECMO flow, and oxygenator function
6. Review of cardiac anatomy, looking specifically at the aortic arch, ductal, and subclavian anatomy

The correct answer is D. Directional flow from the ECMO arterial cannula is the only choice that explains well-oxygenated lower body blood alongside desaturated upper body blood in a patient with normal arch anatomy. Right-to-left shunting across a PDA (choice A) delivers desaturated pulmonary arterial blood to the descending aorta and would produce lower post-ductal (lower extremity) saturation, the opposite of this patient’s findings; furthermore, in tetralogy of Fallot on VA ECMO, ductal flow is typically left-to-right. Methemoglobinemia (choice B) lowers pulse oximetry readings uniformly at every site and cannot produce an inter-extremity gradient; arterial blood gases would also show a normal PaO2. Pulse oximeter artifact (choice C) is excluded by the reliable waveforms and confirmatory arterial blood gases.

REFERENCES

1. Di Nardo M, Stoppa F, David P, Lorusso R, Ranieri VM, Mascia L. Reversed differential cyanosis during veno-arterial extracorporeal membrane oxygenation in infants: the reevaluation of an old phenomenon. Eur J Heart Fail. 2017;19 Suppl 2:117-119. doi:10.1002/ejhf.855

2. Martin TC. Reverse differential cyanosis: a treatable newborn cardiac emergency. Neoreviews (2011) 12 (5): e270–e273.

3. Ramachandra R, Ellison GA, Su F, Punn R. Cannula Positioning in an Infant on Venoarterial Extracorporeal Membrane Oxygenation: A Rare Cause of Reverse Differential Cyanosis. CASE (Phila). 2023;8(1):21-24. Published 2023 Nov 18. doi:10.1016/j.case.2023.09.006

4. Torre DE, Pirri C. Harlequin Syndrome in Venoarterial ECMO and ECPELLA: When ECMO and Native or Impella Circulations Collide - A Comprehensive Review. Rev Cardiovasc Med. 2025;26(8):39992. Published 2025 Aug 26. doi:10.31083/RCM39992